What was found
AFT CARGO COMPARTMENT RH TRANSITION ANGLE UPPER SURFACE HAS CORROSION AROUND NUT PLATE HOLES. FROM STA 727H TO STA 727I. / [01] REMOVED R/H TRANSITION ANGLE FROM 727F PLUS 11? TO STATION 767 PER SRM 53-00-53-2R-6. FABBED NEW TRANSITION ANGLE PER SRM 53-00-53-2R-6;[02] INSTALLED RH TRANSITION ANGLE SECTION AND ALL REPAIR PARTS IAW SRM 53-00-53-2R-6. REF STEP 1 FOR PUSH TEST OF CLICK BOND NUT PLATES.;[03] VERIFIED 2. JOSHUA PHIPPS (TECHNICIAN); 24-JUN-2022 08:28 UTC <BR>INSTALLED RH TRANSITION ANGLE SECTION AND ALL REPAIR PARTS IAW SRM 53-00-53-2R-6. REF STEP 1 FOR PUSH TEST OF CLICK BOND NUT PLATES;[04] INSTALLED ADHESIVELY BONDED NUTPLATES ON 23-JUN-09:00 PER SRM 51-40-10.;[05] COMPLETED INSTALLATION PER 53-00-53-2R-6 AND PER ABOVE SIGN OFFS;[06] COMPLETED INSTALLATION PER SRM 53-00-53-2R-6 AND PER ABOVE SIGN OFFS;[07] 6. PEDRO ALBA (TECHNICIAN); 27-JUN-2022 05:39 UTC<BR>COMPLETED INSTALLATION PER SRM 53-00-53-2R-6 . INSPECTED. SEE ABOVE FOR ALL INDIVIDUAL SIGN OFFS.;[08] 6. PEDRO ALBA (TECHNICIAN); 27-JUN-2022 05:39 UTC<BR>COMPLETED INSTALLATION PER SRM 53-00-53-2R-6 . INSPECTED. SEE ABOVE FOR ALL INDIVIDUAL SIGN OFFS. RII;[09] CORRECTED CORROSION LEVEL FROM LEVEL 3 TO LEVEL 2;[10] C/W;[11] R&R TRANSITION ANGLE PER SRM 53-00-53-2R-6