What was found
A115 DOT#001 FLOOR BOARD PNL 241BF HAS DELAM BUBBLE ON TOP SIDE OF PNL / [01] EVALUATED PANEL 241BF AND FOUND AN AREA OF DELAMINATION ON UPPER SURFACE OF PANEL. FOUND TO BE REPAIRABLE. IAW B737-700 SRM N53-00-50-2R-7 PAR 1A. CLEAN AND PREP FOR REPAIR. IAW B737-700 SRM 53-00-50-2R-7 PAR 3A;C-E. VERIFIED MATERIALS AS: BMS 5-28 (A128478); BMS 9-3 (A24484); BMS 8-201 (A132607).IAW B737-700 SRM 53-00-50-2R-7 TABLE 201. APPLIED POTTING COMPOUND TO OPEN CELLS. NEED OK TO BOND.;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR PLIES. IAW B737-700 SRM 53-00-50-2R-7 PAR 3 F-H. AAR DIGITAL THERMOMETER 30347 150DEG 4HRS.;[04] REPAIRED AREA OF DELAMINATION ON UPPER SURFACE OF PANEL 241BF. IAW B737-700 SRM 53-00 50-2R-7; SRM 53-00-50-2R-0;[05] VERIFIED STEPS 3-4