What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328 LBL 46 WL208.1 FWD GALLEY AND LAV 2022-268016 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328 LBL 46 WL208.1 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG 141A5400 SHEET 26 REV- .SEE INDIVIDUAL SIGN OFFS BELOW;[02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328 LBL 46 WL208.1 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG 141A5400 SHEET 26 REV- . ITEM RII. SEE INDIVIDUAL SIGNS-OFF BELOW.