What was found
L/H STA 663 VAPOR BARRIER WEB CRACKED AT LBL 44 / [01] EVALUATED AND FOUND CRACK AT LBL 44 1' LONG. FOUND TO BE REPAIRABLE IAW 57-10-10-2R-2 STEP 1(C)(NOTE); STEP 2(C)(NOTE) AND SRM 51-70-04-2R-10.<BR><BR>CLEANED AND PREPPED IAW SRM 51-70-04-2R-10 STEP 4 A-C.<BR><BR>VERIFIED MATERIAL IAW SRM 51-70-04-2R-0 REPAIR GENERAL TABLE 203. FIBERGLASS (A24484); RESIN (A120244).<BR><BR>REQUESTING OK TO BOND;[02] VERIFIED ITEM 1<BR>OK TO BOND;[03] BONDED REPAIR PLIES IAW B737 SRM 51-70-04-2R-10; PAR $ STEPS D;E;F; AND G AND SRM 51-70-04-2R-0 REPAIR GENERAL; DIGITAL THERMOMETER 30347; CAL DUE 4/30/23. TAP TEST GOOD.;[04] VERIFIED ITEM 3;[05] OK TO PRIME REPAIR AREA ON AC SIDE;[06] APPLIED PRIMER TO REPAIR IAW B737 AMM 51-21-41-370-804.;[07] VERIFIED STEP 6<BR>AUDIT CW