What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 867+19. / [01] REMOVED FLOOR SUPPORT SPLICE ON AFT CARGO BAY BS887 LBL4 TO RBL20 WL168 IAW SRM 51-40-02;[02] UPON FURTHER INVESTIGATION FOUND TO BE NO ALLOWABLE LIMITS FOR DAMAGE IN SRM. PART TO BE REPLACED PER SRM 51-10-02-0G-0 PARAGRAPH 9.;[03] VERIFIED CORRECTIVE ACTION 3.;[04] RECEIVED ON AFT CARGO BAY FLOOR SUPPORT SPLICE BS 887 LBL 21 ITEM146A7506-17 PO#872160. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG146A7502.<BR>OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4. OK TO INSTALL SPLICE;[06] INSTALLED ON AFT CARGO BAY FLOOR SUPPORT SPLICE BS 887 LBL 21 IAW SRM 51-40-02 AND DWG 146A7502;[07] VERIFIED CORRECTIVE ACTION 6.