What was found
CORROSION ON PASSENGER CABIN FLOORBEAM AT LBL 12 BS 294. / [01] REMOVED CORROSION ON PASSENGER CABIN FLOORBEAM AT LBL 12 BS 294 AREA REWORKED: L: 5' W: 2.1' ORIGINAL THICKNESS 0.100' MATERIAL REMOVED MORE THAN 50% FOUND TO BE OUT OF LIMIT; IAW SRM 53-10-51-1A-1<BR><BR>TOOL USED ID: ATS2473 CAL DUE: 07/2022<BR>TOOL USED ID: ATS1672 CAL DUE: 03/2023;[14] INSTALLED ALL REPAIR PARTS AT FLOOR BEAM BS 294 BETWEEN LBL 21 TO RBL 25 PER SRM 53-10-51-2R-16 REP. 16;[15] VERIFIED CORRECTIVE ACTION STEP 14.;[16] APPLIED FILLET SEAL AND APPLIED CIC AT REPAIR AREA BS 294 FLOORBEAM BETWEEN RBL25 TO LBL 21 PER SRM 53-10-51-2R-16 REP. 16;[17] VERIFIED CORRECTIVE ACTION #16.;[18] VERIFIED MEASUREMENT TABLE.