What was found
CORROSION ON PASSENGER CABIN FLOORBEAM AT LBL 12 BS 312. / [01] REMOVED CORROSION ON PASSENGER CABIN FLOORBEAM AT LBL 12 BS 312 AREA REWORKED: L: 4' W: 2.1' ORIGINAL THICKNESS 0.125 MATERIAL REMOVED MORE THAN 50% FOUND TO BE OUT OF LIMIT; IAW SRM 53-10-51-1A-1<BR><BR>TOOL USED ID: ATS2473 CAL DUE: 07/2022<BR>TOOL USED ID: ATS1672 CAL DUE: 03/2023;[22] INSTALLED ALL REPAIR PARTS ON PASSENGER CABIN FLOOR BEAM AT BS 312 LBL 19 - RBL 23 IAW SRM 53-10-51-2R-17 REPAIR 17;[23] VERIFIED CORRECTIVE ACTION STEPS 21 AND 22.;[24] VERIFY STEP 2;3 AND 4;[25] VERIFY STEP 1;[26] APPLIED FILLET SEAL AND CIC TO THE REPAIR AREA IAW SRM 53-10-51-2R-17 REPAIR 17;[27] VERIFIED COMPLETE STEPS 1 - 4.;[28] VERIFIED MEASUREMENT TABLE.<BR>VERIFIED CORRECTIVE ACTION #26.