What was found
CORROSION ON PASSENGER CABIN SCALE ANGLE AT LBL 60 BS 312+7; BS 312+10; BS 312+13; BS 328+3; BS 328+5; BS 328+10. FWD ENTRY MOP SEAL ATTACH ANGLE. / [01] PARTIALLY COMPLETED STEPS 1-6;[02] STEPS 1 - 6 COMPLETE.<BR> <BR>VERIFIED ALL AREAS OF CORROSION NOTED ARE OUT OF LIMITS PER SRM 53-10-15-1A-1<BR><BR>VERIFIED MEASUREMENT TABLE ENTRIES ARE CORRECT.;[03] REMOVED PASSENGER CABIN SCALE ANGLE (FED MOP SILL ATTACHED ANGLE) BS 308 TO BS 342.5 ; LBL 60 ; WL 209 IAW SRM 51-40-02-0G-0;[04] RECEIVED FED MOP SILL ATTACHED ANGLE P/N 141A8112-20 IAW SRM 51-40-05-0G-0 AND DWG# 141A8110 OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION ITEMS 3 AND 4.<BR>OK TO INSTALL;[06] INSTALLED FED MOP SILL ATTACHED ANGLE P/N 141A8112-20 IAW SRM 51-40-05-0G-0 AND DWG# 141A8110;[07] VERIFIED CORRECTIVE ACTION ITEM 6.;[08] VERIFIED FAULT COMPLETE