What was found
AFT CARGO BAY SHIELD FWD OF CARGO DOOR HAS AREAS OF CORROSION BS767 TO BS787 RBL21 WL156 / [01] EVALUATED CORROSION ON SHIELD BS 767 TO 787 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1. VERIFIED MEASUREMENTS TABLE.;[03] REMOVED DAMAGED SHIELD;LOCATED;DRILLED AND DEBURRED NEW SHIELD AT BS 767-787 RBL 21 WL156 IAW SRM 51-40-02-0G-0;51-40-05-0G-0 AND DWG 146A0081.;[04] VERIFIED CORRECTIVE ACTION 3.;[05] OK TO INSTALL NEW SHIELD.;[06] VERIFIED OK TO INSTALL AND MEASUREMENT TABLE DATA.;[07] INSTALLED NEW SHIELD AFT CARGO BAY BS767 TO BS787 RBL21 WL156; PER SRM 51-40-02-0G-0 AND DWG 146A0081.;[08] VERIFIED CORRECTIVE ACTION 7;[09] VERIFIED COMPLETE