What was found
INTERCOSTAL CRACKED BS 277+8 BL 0 WL 208 / [01] REMOVED CRACKED INTERCOSTAL AT BS 277+8 BL0 WL208 IAW SRM 51-40-02. ALSO; UPDATED MEASUREMENTS.;[02] LOCATED AND DRILLED INTERCOSTAL BS 277-294 BL 0 WL 208 PER SRM 51-40-05-0G-0 AND DRAWING 141A5400.<BR>REQUEST OK TO INSTALL.;[03] VERIFIED CORRECTIVE ACTIONS STEP 2.;[04] OK TO INSTALL GIVEN.;[05] INTALLED INTERCOSTAL BS 277-294 BL 0 WL 208 PER SRM 40-02-0G-0 AND DRAWING 141A5400.;[06] VERIFIED CORRECTIVE ACTIONS STEP 5.