What was found
CORROSION ON ASD MOPSILL BS 947+16-967+18 RBL 57 L 208 / [01] REMOVED CORROSION ON ASD MOPSILL BS 947+16-BS 967+18 WL 208 IN AREA OF 25'X2' . ORGINAL THICKNESS .080 PER SRM 53-70-51-01-1;[02] REFERENCE IS SRM 53-70-15-1A-1;[03] CERTIFIED REFERENCE;[04] REFERENCE IS SRM 53-70-15-1A-1 FOR STEP 1;[05] CERTIFIED REFERENCE TO STEP1;[06] VERIFIED CORRECTIVE ACTIONS STEP 1;4.;[07] UT INSPECTED BLENDED AREA IAW 737 NDTM PART 4 51-00-00 PROCEDURE 2.<BR>REMAINING MATERIAL THICKNESS IS 0.067' ADJACENT TO 0.080'. <BR>EQUIP USED: <BR>-EPOCH 650 ID: ATS2031 CAL DUE: 03/23;[08] MAX MATERIAL REMOVED WAS .013' FROM .080'. OUT OF LIMITS PER SRM 53-70-15-1A-1.;[09] VERIFIED CORRECTIVE ACTION STEP 8.;[10] REMOVED CORROSION DAMAGED ASD MOP SILL FROM BS 907 TO BS 1008 RBL 57 WL 208 IAW SRM51-40-02-0G-0;[11] LOCATED AND DRILLED NEW ASD MOP SILL IAW SRM 51-40-05-0G-0 AND BOEING DWG 147A8501 COUNTERSUNK ALL FASTENER HOLES IAW SRM 51-40-08-0G-0 INSTALLED THRESHOLD NUT PLATES IAW SRM 51-40-02-0G-0;[12] VERIFIED CORRECTIVE ACTIONS STEP 10;11.;[13] APPLIED CHEMICAL CONVERSION COAT AND PRIMED BARE METAL AREAS OF NEW ASD MOP SILL AND REPAIR AREA IAW SRM 51-20-01-0G-0 OK TO INSTALL ASD MOP SILL.;[14] VERIFIED CORRECTIVE ACTION STEP 13. VERIFIED OK TO INSTALL ASD MOP SILL.;[15] INSTALLED NEW ASD MOP SILL IAW SRM 51-40-02-0G-0 AND BOEING DWG 147A8501;[16] CORRECTED PART# IN MEASUREMENT TABLE.;[17] VERIFIED MEASUREMENT TABLE.;[18] VERIFIED CORRECTIVE ACTION 15.