What was found
CORROSION ON FLOOR SUPPORT STA 947+2; RBL 26; WL 208. / [01] REMOVED CORROSION ON FLOOR SUPPORT STA 947+2; RBL 26; WL 208; AREA BLENDED IS 3.4' BY 1.4' PER SRM 51-10-01-02-0. FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS. SRM 51-10-02-0G-0 IS APPLICABLE REPLACEMENT OF PART.;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] REMOVED DAMAGED FLOOR SUPPORT BS947-BS967 RBL26 WL208 I.A.W SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW FLOOR SUPPORT BS947-BS967 RBL26 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 147A5650 OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4; OK TO INSTALL GIVEN.;[06] INSTALLED NEW FLOOR SUPPORT BS947-BS967 RBL26 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 147A5650;[07] VERIFIED MEASUREMENT TABLE.;[08] VERIFIED CORRECTIVE ACTION 6.