What was found
CORROSION ON FLOOR/GALLEY MOUNT SUPPORT; BS 947 - BS 967; RBL 50; WL 208 / [01] VERIFIED APPLICABILITY OF SRM 53-70-51-1A-1 FOR ALLOWABLE DAMAGE LIMITS.;[02] EVALUATED DAMAGE ON FLOOR/GALLEY MOUNT SUPPORT; BS 947 - BS 967; RBL 50; WL 208. DAMAGE REMOVED IN MULTIPLE AREAS WITH LARGEST DAMAGE REMOVAL AREA FOUND TO BE 1' X 1' WITH A MAX DEPTH OF 0.046' FROM ADJACENT THICKNESS OF 0.200'. DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1.;[03] REMOVED DAMAGED FLOOR/GALLEY MOUNT SUPPORT; BS 947 - BS 967; RBL 50; WL 208 PER SRM 51-40-02-0G-0.;[04] LOCATED AND DRILLED NEW FLOOR/GALLEY MOUNT SUPPORT; BS 947 - BS 967; RBL 50; WL 208 PER SRM 51-40-05-0G-0. OK TO INSTALL.;[05] INSPECTED & VERIFIED CORRECTIVE ACTION ITEMS 1; 2 & 4. OK TO INSTALL NEW MOUNT SUPPORT GIVEN.;[06] INSTALLED NEW FLOOR/GALLEY MOUNT SUPPORT; BS 947 - BS 967; RBL 50; WL 208 PER SRM 51-40-02-0G-0 AND BOEING DWG 147A5650.;[07] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 6.;[08] VERIFIED MEASUREMENT FIELDS ARE ACCURATE & COMPLETE.