What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 22 BS 727J+5; BS 727J+10; BS 747+6; BS 747+10; BS 747+14; BS 747+18; BS 767+2; BS 767+6; BS 767+14; BS 767+18. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 747+6' REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.045' FOUND TO BE OUT OF LIMITS PER SRM 53-30-15-1A-1 USING ATS TOOL ID ATS2678 EXP 4/2023. PART WILL BE REMOVED AND REPLACED ON FAULT TTG8Q00DBC71;[02] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 747+6' REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-15-1A-2 USING ATS TOOL ID ATS2678 EXP 4/2023. PART WILL BE REMOVED AND REPLACED ON FAULT TTG8Q00DBC71;[03] UPDATED MEASUREMENT TABLE;[04] VERIFIED CORRECTIVE ACTIONS 1-3<BR>VERIFIED MEASUREMENTS TABLE<BR>VERIFIED FAULT WILL BE RESOLVED ON TTG8Q00DBC71;[05] VERIFIED CORRECTIVE ACTIONS 1-3<BR>VERIFIED MEASUREMENTS TABLE<BR>VERIFIED FAULT WILL BE RESOLVED ON TTG8Q00DBC71