What was found
CABIN FLOOR PANEL 241CF IS DELAMINATED. / [01] EVALUATED AND FOUND MISSING PLIES AT FWD EDGE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP 3 A; C; E-F.<BR><BR>VERIFIED MATERIAL IAW SRM 53-00-50-2R-1 TABLE 201. FABRIC (A24484); RESIN (A133944); POTTING COMPOUND (A128121).<BR><BR>APPLIED POTTING COMPOUND IAW SRM 53-00-50-2R-1 STEP 3 G-J. CURED AT 120 DEGREES (OVEN B0-06 EXP 8-13-22).<BR><BR>REQUESTING OK TO BOND;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEP 3 K-M. CURED AT 150 DEGREES (OVEN B0-06 EXP 8-13-22). TAP TEST GOOD.;[04] REPAIRED CABIN FLOOR PANEL 241CF AT FWD EDGE UPPER SURFACE IAW SRM 53-00-50-2R-0 REPAIR GENERAL AND SRM 53-00-50-2R-1.;[05] VERIFIED STEPS 3-4