What was found
AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS747 TO BS847 LBL21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS ON FLOOR TO SIDEWALL SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 747+10 LBL 21 WL 21; FOUND 0.015 REMOVED FROM ORIG 0.040 IN NUMEROUS 1'X1' AREAS; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATD 2678 DUE 04/2023;[02] CORRECTION TO STEP 1; WL IS 156;[03] VERIFIED ACTION #1;2;[04] VALIDATED APPLICABILITY OF SRM 53-00-53-2R-5;[05] REMOVED DAMAGED PART OF THE ACB L/H FLOOR TO SIDEWALL SUPPORT BS727J+10 TO BS847; LBL21; WL156. PER SRM 53-00-53-2R-5 STEP 4. B & C.;[06] FABRICATED ACB L/H FLOOR TO SIDEWALL SUPPORT AND ALL REPAIR PARTS BS727J+10 TO BS847; LBL21; WL156. PER DWG 146A7500 AND SRM 53-00-53-2R-5 STEPS 4. D. THRU H. FROM BAC1496-377#7075T62 EXT. CLAD LOT#1494598-1. SLICE LOCATION BS727J+10.;[07] VERIFIED CORRECTIVE ACTION #5; 6<BR>VERIFIED MEASUREMENTS;[08] APPLIED CHEMICAL CONVERSION COATING AND PRIMER TO ACB FABRICATED L/H FLOOR TO SIDEWALL SUPPORT AND ALL REPAIR PARTS PER SRM 53-00-53-2R-5 STEP 4. I. AND J. OK TO INSTALL.;[09] VERIFIED CORRECTIVE ACTION #8;[10] INSTALLED FABRICATED ACB L/H FLOOR TO SIDEWALL SUPPORT AND ALL REPAIR PARTS BS727J+10 TO BS847; LBL21; WL156. PER DWG 146A7500 AND SRM 53-00-53-2R-5 STEPS 4. K THRU N.;[11] VERIFIED CORRECTIVE ACTION #10