What was found
CORROSION ON FLOOR SUPPORT STA 949; LBL 52; WL 208; UPPER SURFACE. / [01] NO LIMITS FOUND ON SRM FOR SPECIFIC DAMAGE SRM 51-10-02-0G-0 PAR 9.C REPLACEMENT OF THE PART IS APPLICABLE;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMENT FIELD;[03] REMOVED DAMAGED FLOOR SUPPORT STA 947-986; LBL 52; WL 208 PER SRM 51-40-02-0G-0.;[04] REMOVED FLOOR SUPPROT STA 950; LBL 25-LBL 52; WL 208 FOR ACCESS PER SRM 51-40-02-0G-0.;[05] REMOVED DAMAGED FLOOR SUPPORT STA 947-967; LBL 52; WL 208 PER SRM 51-40-02-0G-0.;[06] CORRECTED BODY STATION 947-967.;[07] LOCATED AND DRILLED NEW FLOOR SUPPORT BS947-BS967 LBL52 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 147A5650. OK TO INSTALL;[08] VERIFIED CORRECTIVE ACTION 7. OK TO INSTALL FLOOR UPPORT.;[09] INSTALLED FLOOR SUPPORT BS947-BS967 LBL52 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 147A5650.;[10] VERIFIED CORRECTIVE ACTION #9 AND STEP 1;[11] UPDATED PARTS USED INFO.;[12] VERIFIED CORRECTIVE ACTION #9 AND STEP 1