What was found
FWD ENTRY MOPSILL IS CRACKED COMMON TO 303 FRAME ON VERTICAL FLANGE LBL 54; WL 209. / [01] NOT ALLOWABLE LIMITS FOUND ON SRM FOR CRACK ON BS303 FED MOPSILL LBL54 WL209 REPLACEMENT OF THE PART IS APPLICABLE PER SRM 51-10-02-0G-0 PAR. 9.C;[02] REMOVE FED MOPSILL I.A.W SRM 51-40-02-0G-0;[03] LOCATED AND DRILLED NEW FED MOPSILL I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 140A9810 OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION 3. OK TO INSTALL THE FED MOP SILL.;[05] VERIFIED MEASUREMENT TABLE.;[06] INSTALLED NEW FED MOPSILL BS270-BS356 WL209 LBL54 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 140A9810 COMPLETED ALL REMOVED AND REPLACED TASK;[07] VERIFIED ITEM 6 CORRECTIVE ACTIONS.;[08] VERIFIED MEASUREMENTS