What was found
CORROSION ON FWD SERVICE DOOR MOPSILL SCUFFPLATE ATTACH ANGLE STA 302-326; RBL 57- RBL 59; WL 209. / [01] REMOVED NUT PLATES COMMON TO FWD SERVICE DOOR MOP SILL SCUFF PLATE ATTACH ANGLE IAW SRM 51-40-02-0G-0 BLENDED CORROSION FROM ATTACH ANGLE IN SEVERAL SPOTS BS 302 TO 326 RBL 57 -59 WL 209 1' X 1' MAX REMOVED .012 FROM ORIGINAL .090 FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-2 STEP 4.A FIG 102 USING DIAL INDICATOR ATS2678 S/N UNKNOWN CAL DUE 04/2023;[02] VERIFIED CORRECTIVE ACTION ITEM 1;[03] REMOVED CORRODED FWD SERVICE DOOR MOP SILL SCUFF PLATE ATTACH ANGLE AT BS 302-326 RBL 57 WL 209 IAW SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED AND COUNTERSUNK AND DEBURRED NEW FWD SERVICE DOOR MOPSILL SCUFFPLATE ATTACH ANGLE STA 302-326; RBL 57-RBL 59; WL 209 PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; SRM 51-40-08-0G-0. OK TO INSTALL.;[05] VERIFIED CORRECTIVE ACTION 4.;[06] VERIFIED MEASUREMENT TABLE.;[07] INSTALLED NEW FWD SERVICE DOOR MOPSILL SCUFFPLATE ATTACH ANGLE STA 302-326; RBL 57-RBL 59; WL 209 PER SRM 51-40-02-0G-0 AND BOEING DWG 141A8310 COMPLETED ALL REMOVED AND REPLACED TASK;[08] VERIFIED ITEM 7 CORRECTIVE ACTIONS.;[09] VERIFIED MEASUREMENTS.;[10] CHANGED MAJOR TO MINOR IN TABLE;[11] CHANGED MAJOR TO MINOR IN TABLE