What was found
CORROSION ON FWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT AT STA 500C+14 ; RBL 25; WL 156 / [01] REMOVED CORROSION ON FWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT AT BS 500C; RBL 25; WL 156 ; WORK AREA ; L 1.0' X W 1.0' X D 0.014' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 ; USE DEPTH GAGE ; ID: ATS 1225; S/N UNKNOWN; DUE: 07/2022;[02] VERIFIED CORRECTIVE ACTION 1;[03] SRM 53-00-53-1A-2 IS APPLICABLE FOR THIS;[04] FABRICATED; LOCATED AND DRILLED NEW FWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT AT BS 500A TO BS 500D ; RBL 25 WL 156 IAW SRM 51-40-05-0G-0 AND DWG 143A7501; ID:0071;REV:-; BAC1496-444#7075T62; LOT#1487676-1; APPLIED CHEMICAL CONVERTION IAW AMM 51-21-41-370-802; OK TO APPLY PRIMER;[05] VERIFIED CORRECTIVE ACTION 1;3 AND 4.;[06] APPLIED PRIMER ON FWD CARGO BAY R/H NEW FLOOR TO SIDEWALL SUPPORT AT BS 500A TO BS 500D ; RBL 25 WL 156 IAW SRM 51-21-72-370-804;[07] VERIFIED CORRECTIVE ACTION STEP 6 COMPLETED;[08] VERIFIED MEASUREMENT TABLE