What was found
R/W L/E PANEL 621YB CONER METAL STRIP DISBONDED / [01] IDENTIFIED PANEL 621YB MATERIAL IAW SRM 57-41-01-0I-4; FIGURE 2; SHEET1; TABLE 2; ITEM [1]. <BR><BR>CLEANED PANEL AND REMOVED FINISH TO EVALUATE DAMAGE IAW AMM 51-21-11-150-815 PARA. 17. C. AND D <BR><BR>REMOVED (2 EA.) BACKUP PLATES TO FACILITATE EVALUATION IAW SRM 51-40-02-0G-0 PARA 4.E. FIG 8. <BR><BR>REMOVED BONDED ALUMINUM FOIL TO FACILITATE EVALUATION IAW SRM 51-70-14-2R-3 PARA 4.A.(1).-(2). <BR><BR>VISUAL INSPECTION FOUND NO SIGNS OF METAL STRIP DISBOND IAW SRM 51-10-02-0G-0 PARA 4. (5).. <BR><BR>INNER SURFACE FOIL TO BE REPLACED IAW 51-70-14-2R-3.<BR><BR>PANEL TO BE REFINISHED IAW AMM 51-21-99-300-802;[02] UPDATED MEASUREMENTS.;[03] CORRECTION FOR LINE 1; 'INNER SURFACE FOIL TO BE REPLACED IAW 51-70-14-2R-3' SHOULD READ 'INNER SURFACE FOIL TO BE REPLACED IAW SRM 51-70-14-2R-3.';[04] VERIFIED CORRECTIVE ACTIONS 1-3;[05] UPON FURTHER INVESTIGATION FOUND CRACK FROM FASTENER HOLE TO EDGE OF PANEL AT FWD; I/B CORNER THAT IS OUT OF ALLOWABLE LIMITS IAW SRM 57-41-01-1A-1 PARA 4. A. (5) (A). <BR><BR>REPAIR TO BE COMPLETED IAW SRM 51-70-05-2R-6 AS GIVEN IN SRM 57-41-01-2R-1 PARA 4. B. (2) AND TABLE 202.;[06] VALIDATED REPAIR OF SRM 51-70-05-2R-6 AS GIVEN IN SRM 57-41-01-2R-1 PARA 4. B. (2) AND TABLE 202;