What was found
INTERCOSTAL BETWEEN STA. 312-328 LBL 45.60 IN FWD GALLEY FLOOR STRUCTURE IS CRACKED / [01] REMOVED INTERCOSTAL BETWEEN STATION 312-328 TO F.M.O;[02] LOCATED AND DRILLED NEW INTERCOSTAL P/N:141A5410U140 AT STATION 312-328 AND LBL 45.60. ALL WORK REFERENCE TO SRM 51-20-02/0G01.;[03] C/W INSPECTION LOCATED AND DRILLED NEW INTERCOSTAL P/N:141A5410U140 AT STATION 312-328 AND LBL 45.60. ALL WORK REFERENCE TO SRM 51-20-02/0G01. <BR>OK TO INSTALL INSPECTION C/W;[04] INSTALLED NEW INTERCOSTAL PER SRM 51-40-02.;[05] C/W INSPECTION <BR>INSTALLED NEW INTERCOSTAL PER SRM 51-40-02.