What was found
CORROSION ON FWD ENTRY DOOR AFT GIRT BAR ATTACH FITTING AT STA 344; LBL 59; WL 208.6. / [01] UPDATED MEASUREMENT TABLE;[02] REMOVED CORROSION ON UPPER SURFACE OF GIRT BAR FITTING IAW SRM 51-10-02-0G-0. DEPTH OF REMOVAL 1X1X.012'. SRM DOES NOT HAVE REMOVAL LIMITS FOR ATTACHMENT FITTINGS. REMOVE AND REPLACE PER SRM. MEASURED WITH ATS 401; S/N UNKNOWN; DUE 10/2022;[03] UPDATED MEASUREMENT TABLE ON LEVEL CLASSIFICATION AND REPAIR TYPE;[04] CERTIFY;[05] VERIFIED CORRECTIVE ACTIONS #2 AND #3<BR>VERIFIED MEASUREMENT TABLE;[06] REMOVED FWD ENTRY DOOR ATTACH FITTING AT AST 344; LBL 59; WL 208.6 IAW SRM 51-40-02-OG-0;[07] CERTIFY;[08] OK TO INSTALL NEW GIRT BAR ATTACH FITTING.;[09] CORRECTED MEASUREMENT TABLE FROM MAJOR TO MINOR; LEVEL 1 CORROSION;[10] CERTIFY;[11] OK TO INSTALL NEW GIRT BAR ATTACH FITTING.;[12] INSTALLED NEW GIRT BAR FITTING IAW SRM 51-40-02-0G-0 USING STANDARD TORQUE PER AMM 20-50-11-910-801. ATS1639; S/N 1062571; DUE 11/2022;[13] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 12.;[14] COMPLETE