What was found
CABIN; STA.947.5 +2 LBL 52; HARD POINT FITTING ON INTERCOSTAL HAS AREA OF CORROSION. / [01] REMOVED CORROSION ON INTERCOSTAL AT STATION 947.5 + 2 LBL 52; REMOVED 0.047? OF 0.215? FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1;[02] VERIFIED DAMAGE REMOVAL IS OUT OF LIMITS.;[03] LOCATED/DRILLED FASTENER HOLES IN REPLACEMENT INTERCOSTAL AND INSTALLED NUT-PLATES IAW SRM 51-40-02.;[04] R/R INTERCOSTAL IAW SRM 51-40-02.;[05] R/R INTERCOSTAL IAWSRM 51-40-02.;[06] C/W INSPECTION<BR>R/R INTERCOSTAL IAW SRM 51-40-02.