What was found
CORROSION FOUND AT AFT CARGO FLOOR STRIP AT STA 767 +5 BETWEEN RBL 21 AND LBL 21 W.L. 155.5 AROUND FASTENER HOLES. / [01] FOUND EXFOLIATION AT AFT CARGO FLOOR STRIP AROUND THE FASTENERS OUT OF LIMITS AS PER REF B737-700 SRM 53-00-53-1A-2;[02] RECEIVED AND VERIFIED NEW FLOORBOARD SPLICE P/N 146A9401-4 AS PER REFERENCE B737-700 SRM 53-60-53-0L-2 AND DWG #146A9401.<BR>FLOORBOARD SPLICE WILL BE INSTALL IN TASK CARD # TTG8Q004BZAN.;[03] VERIFIED STEP#2 ABOVE.