What was found
GENERAL VISUAL INSPECTION OF THE INTERIOR SURFACE OF THE 193B FAIRING PANEL REVEALS AREAS OF DELAMINATION; PRESENT ON THE FAIRING PANEL AT FASTENER LOCATIONS NUMBER 3; 5; 9; 19; 20; 34; 35; 36; 37; 38 / [01] DRILLED AND COUNTERSUNK HOLES ON NEW PANEL PER AMM 51-40-05. CONTINUE WITH FAIRING PANEL INSTALLATION 53-51-21-400-802 STEP 5.;[02] INSTALLED PANEL AS REQUIRED REF AMM 53-51-21.