What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727E+14; BS 727E+18; BS 747+2; BS 747+6; BS 747+14; BS 767+10; BS 767+14. / [01] VERIFIED SRM 53-00-53-1A-2 ALLOWABLE DAMAGE IS APPLICABLE. <BR>REMOVED CORROSION FROM ACB L/H FLOOR TO SIDEWALL SUPPORT WITH ORIGINAL THICKNESS 0.040'.<BR>BS727E+14 L= 0.900' W= 1' D= 0.009' FOUND OUT OF LIMITS <BR>BS727E+18 L= 1.200' W= 1' D= 0.007' FOUND OUT OF LIMITS <BR>BS747+2 L= 2' W= 1' D= 0.004' FOUND IN LIMITS<BR>BS747+6 L= 2' W= 1' D= 0.002' FOUND IN LIMITS <BR>BS747+14 L= 1.100' W= 1' D= 0.005' FOUND OUT OF LIMITS <BR>BS767+10 L= 0.900' W= 1' D= 0.008' FOUND OUT OF LIMITS <BR>BS767+14 L= 1.300' W= 0.900' D= 0.006' FOUND OUT OF LIMITS <BR>TOOL= ID: ATS2472 S/N: UNKNOWN DATE: 12/2021 DUE: 12/2022<BR>IAW SRM 51-10-02 AND SRM 53-00-53-1A-2;[04] :FABRICATED ; LOCATED AND DRILLED REPLACEMENT ACB FLOOR TO SIDEWALL SUPPORT USING BAC1496-377#7075T62 LOT:1473823-1 IAW SRM 51-40-05-0G-0;; SRM 53-00-53-2R-6 AND DWG 1467502 REV:-. FABRICATED FLOOR TO SIDEWALL SUPPORT SPLICE REPAIR AT B/S BTW 727E TO 747 LBL 21 USING BAC1496-377#7075T62 LOT:1473823-1 IAW SRM 53-00-53-2R-6 AND SRM 51-40-05. [10] INSTALLED SPLICE REPAIR AT SIDEWALL SUPPORT LBL 21; WL 156 ;BTW 727E TO 747 ACB IAW SRM 51-40-02 SRM 53-00-53-2R-6;