What was found
CRACKED INTERCOSTAL AT FWD CABIN BS294+6 RBL31. MARKED. / [01] REMOVED HI-LOCKS FROM INTERCOSTAL AT FWD CABIN BS 294+6 RBL 31 <BR>IAW SRM 51-40-02-0G-0.;[02] VERIFIED APPLICABILITY PER SRM 53-00-04-1A-1 AND BOEING DWG 141A5400<BR>REPAIR PER REPLACEMENT PER SRM 53-00-04-1A-1<BR>LOCATED AND MATCH DRILLED NEW INTERCOSTAL AT FWD CABIN BS294+6 RBL31 WL208 IAW SRM 51-40-05 AND BOEING DWG 141A5400;[03] VERIFIED CORRECTIVE ACTIONS #1 AND 2; AND UPDATING OF MEASUREMENTS;[04] VERIFIED CORRECTIVE ACTION 1-3 OK TO INSTALL;[05] INSTALLED INTERCOSTAL AT FWD CABIN BS294+6 RBL31 IAW SRM 51-40-02 AND BOEING DWG 141A5400;[06] VERIFIED;[07] VERIFIED CORRECTIVE ACTION ITEM 5.<BR><BR>** FLOOR PANEL FASTENER HOLES REQUIRE LOCATION AND DRILLING.;[08] VERIFIED APPLICABILITY PER SRM 53-00-04-1A-1 AND BOEING DWG 141A5400<BR>REPAIR PER REPLACEMENT PER SRM 53-00-04-1A-1<BR>LOCATED AND MATCH DRILLED NEW INTERCOSTAL AT FWD CABIN BS294+6 RBL31 WL208 IAW SRM 51-40-05 AND BOEING DWG 141A5400 <BR>UPDATED MEASUREMENTS TABLE.;[09] VERIFIED;[10] LOCATED AND DRILLED FLOOR PANEL HOLES IAW SRM 51-40-05-0G-0;[11] VERIFIED CORRECTIVE ACTION #5; 8<BR>VERIFIED MEASUREMENTS