What was found
FWD FLOOR PANEL 221DF UPPER SURFACE HAS AREAS OF PULLED STRANDS. / REMOVED AN APPROX. 19'X9' AREA OF DAMAGED TOOLSIDE PLY DAMAGE LOCATED 10' FROM THE OUTBOARD EDGE AND 14' FROM THE FORWARD EDGE WITH NO DISBOND; EXPOSED CORE CELLS OR CONTAMINATION NOTED; ALSO REMOVED 19 EA INSERTS FROM PANEL; WORK PERFORMED IAW SRM 53-00-50-2R-1 PARAGRAPH 3.A-F.;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1.;[03] VERIFIED CORRECTIVE ACTION #1; 2;[04] FABRICATED REPAIR PLIES FROM BMS9-3 TYPE H2 CLASS 7 STYLE 1581 LOT NUMBER 1493221-1 IAW SRM 53-00-50-2R-1 PARAGRAPH 3.K.(1).(A). OK TO INSTALL REPAIR PLIES.;[05] VERIFIED CORRECTIVE ACTION #4;[06] INSTALLED PLIES USING BMS8-201 LOT NUMBER 1494809-1; AND VACUUM BAGGED; VERIFIED SATISFACTORY 5X5 SUING VACUUM GAUGE ID: ATS2438 DUE: 03/2023; WORK PERFORMED IAW SRM 53-00-50-2R-1 PARAGRAPH 3.K.(1).(B-C) AND L.(1).(A-C).;[07] VERIFIED CORRECTIVE ACTION #6;[08] CURED PLIES UNDER HEAT LAMP USING THERMOMETER ID: ATS1174 DUE: 03/2023; WORK ACCOMPLISHED IAW SRM 53-00-50-2R-1 PARAGRAPH 3.M.;[09] UNBAGGED PANEL AND INSTALLED THROUGH INSERTS USING BMS5-107 LOT#AK1KP9159K AND INSTALLED BLIND INSERTS USING BMS5-28 TYPE 19 LOT#AK2AP8108K IAW SRM 53-00-50-2R-1 PARA 3M-N;[10] CURED BLIND INSERTS USING HOTBONDER ID: IS000678 CAL DUE DATE 04/2023 AND THROUGH INSERTS WITH A HEAT LAMP AND THERMOMETER ATS2208 CAL DUE DATE 10/2022 IAW SRM 53-00-50-2R-1 PARA 3N;[