What was found
FWD CARGO BAY BAFFLE CRACKED BS 500B - BS 500C LBL 25 / [01] SRM 53-00-53-1A-2 IS APPLICABLE FOR THIS ; CRACK FOUND OUT OF LIMITS;[02] REMOVED FWD CARGO BAY BAFFLE FROM BS 500B TO BS 500C ; LBL 25 IAW 51-40-02-0G-0;[03] LOCATED AND DRILLED NEW FWD CARGO BAY BAFFLE P/N 143A7510-11 IAW SRM 51-40-05-0G-0 AND DWG 143A7505; ID:0005; REV:B; OK TO INSTALL NEW BAFFLE;[04] VERIFIED CORRECTIVE ACTIONS 1 AND 3.<BR>OK TO INSTALL;[05] INSTALLED NEW FWD CARGO BAY BAFFLE BETWEEN BS 500B TO BS 500C ; LBL25 IAW SRM 51-40-02-0G-0 AND DWG 143A7505; ID:0005; REV:B;[06] VERIFIED CORRECTIVE ACTION 5;[07] VERIFIED MEASUREMENT TABLE