What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 867+3; BS 867+6; BS 867+16. / [01] SRM 53-00-53-1A-2 FOUND TO BE APPLICABLE FOR THIS EVALUATION. REMOVED DAMAGE FROM THE FOLLOWING LOCATION: BS867+3 1.3LX1.0W D:0.006; BS867+6 1.3LX1.1W D:0.006; BS867+16 1.7LX1.0 D:0.004 ORIGINAL THICKNESS IS 0.040 PART FOUND TO BE OUT OF LIMITS. IAW SRM 51-10-02; SRM 53-00-53-1A-2. BAC1496-377 CAL TOOL INFO. ID:ATS2595 S/N F03295; EXP; 02/2023;[02] VERIFIED CORRECTIVE ACTION #1;[03] FABRICATED ; LOCATED AND DRILLED NEW AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BETWEEN BS 867 T0 BS 947.5 ; FROM BAC1496-377 7075-T62 ; LOT# 1494598-1 ; IAW SRM 51-40-05-0G-0 AND DWG 146A7501; ID:0006;REV:A; APPLIED CHEMICAL CONVERSION AMM 51-21-41-370-802; OK TO APPLY PRIMER;[04] VERIFIED CORRECTIVE ACTION #3;[05] APPLIED PRIMER ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 FROM BS 867 TO BS 947.5 IAW AMM 51-21-72-370-804;[06] VERIFIED CORRECTIVE ACTION #5<BR>VERIFIED MEASUREMENT TABLE