What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 887+11; BS 887+19; BS 907+2; BS 907+13; BS 927+2. / [01] SRM 53-00-53-1A-2 FOUND TO BE APPLICABLE FOR THIS EVALUATION. REMOVED DAMAGE FROM THE FOLLOWING LOCATION: BS887+11 1.2LX1.0W D:0.008; BS887+19 0.6LX0.6W D:0.005; BS905+2 1.2LX0.5W D:0.010; BS905+13 1.1LX0.6W D0.004; BS927+2 0.8LX0.7W D:0.006 IAW SRM 51-10-02; SRM 53-00-53-1A-2. ORIGINAL THICKNESS IS 0.040 PART FOUND TO BE OUT OF LIMITS. IAW SRM 51-10-02; SRM 53-00-53-1A-2. BAC1496-377 CAL TOOL INFO. ID:ATS2595 S/N F03295; EXP; 02/2023;[02] VERIFIED CORRECTIVE ACTION #1;[03] JOB WILL BE ACCOMPLISH ON CUSTMER CARD NBR: TTG8Q00DDBZ4;[04] UPDATED MEASUREMENTS;[05] UPDATED MEASUREMENTS;[06] VERIFIED CORRECTIVE ACTION #3 AND MEASUREMENT FIELD