What was found
CORROSION ON AFT CARGO BAY THRESHOLD AT RBL 26 BS 787+13; RBL 26 BS 807+2; RBL 26 BS 807+4; RBL 26 BS 807+6; RBL 26 BS 807+17; RBL 26 BS 807+19; RBL 26 BS 827+4; RBL 24 BS 827+16; RBL 20 BS 827+19. / [01] REMOVED CORROSION AT<BR>BS 787+13 0.004'<BR>BS 807+2 0.005'<BR>BS 807+4 0.004'<BR>BS 807+6 0.002'<BR>BS 807+17 0.002'<BR>BS 807+19 0.004'<BR>BS 827+4 0.006' (THE DEEPEST DAMAGE)<BR>BS 827+16 0.006' (THE DEEPEST DAMAGE)<BR>BS 827+19 0.004'<BR><BR>IAW SRM 51-10-02-0G-0;[02] VERIFIED APPLICABILITY IAW SRM 53-60-15-01-1 AND SRM 53-60-15-1A-1;[03] ORIGINAL MATERIAL THICKNESS : 0.050' THE DEEPEST DAMAGE REMOVED : 0.006' REMAINING THICKNESS : 0.044' AT BS 827+4 AND BS 827+16.<BR>DAMAGE EXCEED 10% OF ORIGINAL MATERIAL THICKNESS. FOUND TO BE OUT OF LIMIT IAW SRM 53-60-15-1A-1<BR><BR>CALIBRATION TOOL DEPTH GAUGE<BR>ID : ATS401<BR>S/N : UNKNOWN<BR>DUE : 10/2022;[04] VERIFIED CORRECTIVE ACTIONS 1-3;[05] RECEIVED NEW THRESHOLD AT ACB ITEM: 146A8123U25 LOT: 1496302-2. LOCATED AND DRILLED NEW THRESHOLD IAW SRM 51-40-05 AND DWG 146A8123 ID: 0006 REV: C;[06] VERIFIED CORRECTIVE ACTION #5;[07] LOCATED; DRILLED; AND COUNTERSANK NEW THRESHOLD IAW SRM 51-40-05; SRM 51-40-08 AND DWG 146A8123 ID: 0006 REV: C;[08] UPDATED MEASUREMENTS PARAMETERS;[09] FILLED OUT PARTS REQ;[10] VERIFIED CORRECTIVE ACTION #7-9; VERIFIED MEASUREMENT FIELD.