What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 747+2; BS 747+5; BS 747+9; BS 747+14. / [01] REMOVED DAMAGE FROM THE FOLLOWING LOCATION: BS747+2 1.0L X 0.7W D:0.03; BS747+5 0.8L X 0.6W D: 0.04; BS747+9 0.8L X 0.6W D: 0.06; BS747+14 1.0L X 0.7W D: 0.06;IAW SRM 51-10-02; SRM 53-00-53-1A-2. PART FOUND TO BE OUT OF LIMIT.;[02] CAL TOOL INFO. ID:ATS2595 S/N F03295; EXP; 02/2023;[03] SRM 53-00-53-1A-2 IS FOUND TO BE APPLICABLE FOR THIS EVALUATION;[04] ORIGINAL THICKNESS IS 0.40 IAW BAC1496-377;[05] CORRECTION TO LINE 1.REMOVED DAMAGE FROM THE FOLLOWING LOCATION: BS747+2 1.0L X 0.7W D:0.003; BS747+5 0.8L X 0.6W D: 0.004; BS747+9 0.8L X 0.6W D: 0.006; BS747+14 1.0L X 0.7W D: 0.006;IAW SRM 51-10-02; SRM 53-00-53-1A-2. PART FOUND TO BE OUT OF LIMIT.;[06] CORRECTION TO LINE 4 ORIGINAL THICKNESS IS 0.040 IAW BAC1496-377;[07] VERIFIED CORRECTIVE ACTION 1-6;[08] JOB WILL BE ACCOMPLISH ON CUSTMER CARD NBR: TTG8Q00DDCS3;[09] UPDATED MEASUREMENTS;[10] UPDATED MEASUREMENTS;[11] VERIFIED CORRECTIVE ACTION #8 AND MEASUREMENT FIELD