What was found
CORROSION ON SUPPORT STRAP AT MID CABIN ABOVE MLG WELL BS707 LBL63. MARKED / [01] REMOVED CORROSION ON STRAP IN A 1'X1' AREA IAW SRM 51-10-02-0G-0. SRM DOES NOT HAVE LIMITS FOR STIFFNER/ANGLES ON CREASE BEAM WEB. ORIGINAL THICKNESS IS .071';[02] NDI VERIFY REMAINING THICKNESS.;[03] VERIFIED CORROSION REMOVAL AT REWORK AREA PER SRM 51-10-02-0G-0.;[04] HFEC INSPECTED BLENDED AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>NO CRACKS NOTED.<BR><BR>HFEC INSPECTED OPEN HOLES IAW 737 NDTM PART 6 51-00-00 PROCEDURE 16.<BR>NO CRACKS NOTED.<BR><BR>UT INSPECTED BLENDED AREA IAW 737 NDTM PART 4 51-00-00 PROCEDURE 2.<BR>REMAINING MATERIAL THICKNESS IS 0.069' ADJACENT TO 0.071'.<BR><BR><BR>EQUIP USED:<BR>-NORTEC 600 ID: ATS2353 CAL DUE: 01/23<BR>-MINIMITE ID: IS000934 CAL DUE: 08/22<BR>-EPOCH 650 ID: ATS2031 CAL DUE: 03/23;[05] REFER TO FAULT TTG8Q00DDX00 WHERE EA22-153-02114 WAS ADDED AS A SUBTASK;[06] VERIFIED CORRECTIVE ACTION 5. NO FURTHER ACTION REQUIRED.