What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY RBL 23 BS400 - BS420. MARKED. / [01] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-53-1A-2.;[02] REMOVED CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 23 BS 400 DIMENSIONS L=1' W= 0.750 DEPTH:0.010' IAW SRM 51-10-02 PARAGRAPH 15 ; EVALUATED REWORKED AREA ;ORIGINAL MATERIAL THICKNESS 0.040' REMAINING THICKNESS : 0.030' AND FOUND TO BE OUT LIMITS; ALLOWABLE DAMAGE IAW SRM 53-00-53-1A-2;TOOL USED MICROMETER ID ATS400 S/N UNKNOWN DUE 08/2022.;[03] :FABRICATED ; LOCATED AND DRILLED FCB RBL 23 BS 400 TO BS 420 FLOOR TO SIDEWALL SUPPORT USING BAC1496-444#7075T62 LOT:1490548-1 IAW SRM 51-40-05-0G-0;; AND DWG 143A7501 REV:-. APPLY CHEMICAL CONVERSION COATING AND PRIMER.;[04] UPDATED MEASUREMENTS;[05] VERIFIED CORRECTIVE ACTIONS 3 AND 4.;[06] APPLIED CHEMICAL CONVERSION COATING AND PRIMER ON FCB FLOOR TO SIDEWALL SUPPORT AT RBL 23 WL 156; BS 400 TO BS 420 IAW SRM 51-20-01 AND AMM 51-21-72-370-804;[07] VERIFIED CORRECTIVE ACTION #6;[08] VERIFIED CORRECTIVE ACTION 2 AND MEASUREMENT TABLE.