What was found
CORROSION ON AFT CARGO BAY RAIL AT BS 887+16 RBL 8. / [01] REMOVED CORROSION ON ACB ON RAIL BS 887+16' RBL 8 IN L=1' X W=1' X D=0.009' FROM ORIGINAL TICKNESS OF 0.063' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 PAR 4.A. FIG 103. USED TOOL :<BR>ID:ATS601 S/N:87172291 DATE:06/2022 DUE:06/2023;[02] VERIFIED CORRECTIVE ACTION 1 COMPLETED;[03] REMOVED AFT BAY RAIL BS 887-947 RBL 8 IAW SRM 51-40-02-0G-O;[04] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMITS ON AFT CARGO BAY RAIL AT BS 887+16 RBL 8 IAW SRM 53-00-53-1A-2;ALLOWABLE DAMAGE 2;[05] CORRECTION FOR CORRECTIVE ACTION #4 VERIFIED SRM 53-00-53-2R-4 IS APPLICABILITY FOR ACB -RAIL FLOOR BEAM REPAIR. BETWEEN STA 887-907; RBL 8.;[06] FABRICATED ALL REPAIR PARTS FOR ACB RAIL AT BS 887 TO BS 907+ 6 RBL 8 WL 170; MATERIAL USED BAC1509-100146#7075T76511 LOT#1456074-1 EXTRUSION; SPLICE PN 53100004-001 PO#838646/1 LOCATED AND DRILLED ALL REPAIR PARTS BETWEEN BS 887- BS 907+6 IAW SRM 53-00-53-2R-4 REPAIR 4 AND SRM 51-40-05. OK TO APPLY CHEMICAL CONV. COATING AND PRIMER TO REWORKED AREA AND PARTS.[17] INSTALLED ALL REPAIR PARTS FOR ACB RAIL AND SPLICE AT BS 887 TO BS 907+ 6 RBL 8 WL 170; IAW SRM 53-00-53-2R-4 REPAIR 4 AND SRM 51-40-02 DWG 147A7500 REV:- AND DWG146A7500 REV:A;[18] VERIFIED MEASUREMENT TABLE;[19] VERIFIED CORRECTIVE ACTION #17