What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727A+15; BS 727B+14; BS 727C+2; BS 727C+5; BS 727C+10; BS 727D+5; BS 727D+16; BS 727E+10. / [01] VERIFIED SRM 53-00-53-1A-2 ALLOWABLE DAMAGE IS APPLICABLE. <BR>REMOVED CORROSION FROM ACB L/H FLOOR TO SIDEWALL SUPPORT WITH ORIGINAL THICKNESS 0.040'.<BR>BS 727A+15 L= 0.900' W= 1' D= 0.008' FOUND OUT OF LIMITS <BR>BS 727B+14 L= 0.800' W= 0.900' D= 0.006' FUND OUT OF LIMITS <BR>BS 727C+2 L= 1.200' W= 1' D= 0.005' FOUND OUT OF LIMITS <BR>BS 727C+5 L= 2' W= 1' D= 0.003' FOUND IN LIMITS <BR>BS 727C+10 L= 1.400' W= 1' D= 0.008' FOUND OUT OF LIMITS<BR>BS 727D+5 L= 0.900' W= 1' D= 0.009' FOUND OUT OF LIMITS<BR>BS 727D+16 L= 1' W= 1' D= 0.001 FOUND IN LIMITS<BR>BS 727E+10 L= 2' W= 1' D= 0.004 FOUND IN LIMITS <BR>TOOL= ID: ATS2472 S/N: UNKNOWN DATE: 12/2021 DUE: 12/2022<BR>IAW SRM 51-10-02 AND SRM 53-00-53-1A-2;;[06] FABRICATION OF REPLACEMENT FLOOR TO SIDEWALL SUPPORT BS727-847 LBL 21 IS ACCOMPLISHED ON CUSTOMER CARD TTG8Q00DDBZX;[07] EDIT MEASUREMENTS;[08] VERIFIED CORRECTIVE ACTION #6; VERIFIED MEASUREMENTS;[09] UPDATED MEASUREMENTS