What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727+11; BS 727+14; BS 727+18; BS 727A+10; BS 727A+14; BS 727B+2; BS 727B+6; BS 727B+10; BS 727C+2; BS 727C+6. / [01] REMOVED DAMAGE FROM THE FOLLOWING LOCATION: BS727+11 0.7LX0.6W D:0.09; BS727+14 0.8LX0.7W D:0.03; BS727+18 0.9LX0.7W D:0.07; BS727A+10 0.6LX0.5W D:0.06; BS727A+14 0.9LX0.7W D:0.04; BS727B+2 1.2LX0.6W D:0.04; B727B+6 0.7LX0.55W D:0.09; BS727B+10 0.8LX0.6W D0.05; BS727C+2 0.7LX0.7W D:0.02; BS727C+6 0.8LX0.6W D:0.14 IAW SRM 51-10-02; SRM 53-00-53-1A-2. ORIGINAL THICKNESS IS 0.40 PART FOUND TO BE OUT OF LIMIT. SRM 53-00-53-1A-2; BAC1496-377 IS FOUND TO BE APPLICABLE FOR THIS EVALUATION. CAL TOOL INFO. ID:ATS2595 S/N F03295; EXP; 02/2023;[05] FABRICATED ; LOCATED AND DRILLED NEW AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BETWEEN BS 727+4 T0 BS 767 ; FROM BAC1496-377 7075-T62 ; LOT# 1494598-1 ; IAW SRM 51-40-05-0G-0 AND DWG 146A7502; ID:0026;REV:-; APPLIED CHEMICAL CONVERSION AMM 51-21-41-370-802; OK TO APPLY PRIMER;[06] FABRICATED ; LOCATED AND DRILLED NEW AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AND SPLICE AT RBL 21 BETWEEN BS 727+4 T0 BS 767 ; FROM BAC1496-377 7075-T62 ; LOT# 1494598-1 ; IAW SRM 51-40-05-0G-0 AND DWG 146A7502; ID:0026;REV:-; APPLIED CHEMICAL CONVERSION AMM 51-21-41-370-802; OK TO APPLY PRIMER;