What was found
FWD CABIN FLOOR PANEL 222DF HAS PULLED THROUGH INSERTS / [01] IDENTIFIED FWD CABIN FLOOR PANEL 222DF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 2 TABLE 2. FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F. DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>REMOVED 13 EACH INSERTS TO FACILITATE REPAIRS; REMOVED DAMAGED SKINS/CORE ON 2 EACH LOWER SURFACE OUTBOARD EDGE; AND CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1 PARA 3.A-F.;[05] POTTING COMPOUND CURED SURFACE SANDED & CLEANED IAW SRM 53-00-50-2R-1 PARA 3 STEPS H; I; & J . PER GENERAL REPAIR SECTION 53-00-50-2R-0 ELEVATED TEMPERATURE CURE TABLE 203 PAGE 2 REF CAL TOOL THERMOMETER ID ATS1776 SN 34910031WS CAL DUE 08/2022 .;[06] USING BMS9-3 STYLE 1581 GLASS LOT 149322-1 & BMS8-201 TYPE III RESIN LOT AK2CP8139K FABRICATED & APPLIED REPAIR PLIES IAW SRM 53-00-50-2R-1 PARA 3 . K . (1) STEPS (A)-(C). OK TO LAY UP .;[07] VERIFIED CORRECTIVE ACTIONS 5 AND 6<BR><BR>OK TO LAY UP REPAIR PLIES;[08] LAID UP THE REPAIR VACUUM BAGGED ;LEAK CHECKED & SET TO CURE IAW SRM 53-00-50-2R-1 PARA 3 . L. STEPS (A)-(C).;[09] VERIFIED CORRECTIVE ACTION 8;[10] CURED THE REPAIR PLIES IAW SRM 53-00-50-2R-1 PARA 3 . M. (1) STEPS A & B.;[11] CALIBRATED TOOLS USED CORRECTIVE ACTION 10: THERMOMETER ID ATS1777<BR>SN 3491002WS CAL DUE 08/2022 . VACUUM GAGE ID ATS2438 SN UNK CAL DUE 03/2023.