What was found
CORROSION ON FLOOR SUPPORT BS 309; LBL 12; WL 208 / [01] REMOVED CORROSION FROM INTERCOSTAL BS 309 LBL 12 WL 208 IN REA OF 1'X0.05'X0.491' DEEP FOUND TO BE OUT OF LIMIT IAW SRM 53-10-51-1A-1 DET.4E FIG 105-C <BR>TOOLS USED MICROMETER ID:ATS1617; S/N:65093024; DUE 10/2022;[02] INSPECTED AND VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED FLOOR SUPPORT INTERCOSTAL AT BS 294.5 TO BS 312 LBL 12 WL 208 IAW SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW INTERCOSTAL FLOOR SUPPORT AT BS 294.5 TO BS 312 LBL 12 WL 208 IAW SRM 51-40-05-0G-0 AND DWG 141A5600; OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4; OK TO INSTALL GIVEN.;[06] REINSTALLED NEW INTERCOSTAL FLOOR SUPPORT AT BS 294.5 TO BS 312 LBL 12 WL 208 IAW SRM 51-40-02-0G-0 AND DWG 141A5600 CARD IS COMPLETED.;[07] VERIFIED CORRECTIVE ACTION STEP 6.;[08] VERIFIED MEASUREMENT TABLE AND TASK CARD COMPLETE.