What was found
DUE TO REPAIR OF BS 986 FLOORBEAM; AT SPLICE LOCATION;PASSENGER CABIN FLOOR PANEL 242VF HAS 2 EACH INSERTS THAT DOES NOT ALIGN WITH HOLES IN STRUCTURE= FWD EDGE OF PANEL-MARKED / [01] IDENTIFIED PANEL 242VF IAW SRM 53-00-50-0I-1 FIGURE 6 TABLE 6<BR><BR>DAMAGED AREA EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 E(2)<BR><BR>DAMAGE IS REPAIRABLE IAW SRM 53-00-50-2R-1<BR><BR>REMOVED (3EA) THROUGH INSERTS TO FACILITATE REPAIR<BR>REMOVED DAMAGE FROM UPPER SURFACE MEASURING 15'X3'; CLEANED; WITH NO CONTAMINATION NOTED IAW SRM 53-00-50-2R-1 PAR.3 A-F 08] RELOCATION OF INSERT HOLES REQUIRES REPAIR TO BOTH SKINS AND CORE REPAIR TO BE ACCOMPLISHED PER SRM 53-00-50-2R-6 <BR><BR>REMOVED POTTING COMPOUND FROM INSERT HOLES; FABRICATED CORE PLUGS FROM BMS8-124 TYPE 5 GRADE 9 LOT#1287137 AND UPPER SURFACE REPAIR PLIES FROM BMS9-3 H2 LOT#1493221-1; OK TO INSTALL IAW SRM 53-00-50-2R-6 PARA 3C-G;[13] CURED; UNBAGGED AND SANDED REPAIR FLUSH WITH INITIAL SURFACE; CLEANED REPAIR AREA AND FABRICATED REPAIR PLIES FOR LOWER SURFACE FROM BMS9-3 H2 LOT#1493221-1; OK TO INSTALL IAW SRM 53-00-50-2R-6 PARA 3I-K<BR><BR>USED THERMOMETER ATS2208 CAL DUE DATE 10/2022;[16] INSTALLED REPAIR PLIES USING BMS8-201 TYPE 4 LOT#AK2CP8139K; VACUUM BAGGED; CHECKED FOR LEAKS; LEAK CHECKED GOOD USING VACUUM GAUGE ATS2107 CAL DUE DATE 09/2022 IAW SRM 53-00-50-2R-6 PARA 3K-L;