What was found
CRACK FLOOR STRUCTURE ANGLE LOCATED BS 692 AT BL 0 AT PASSENGER CABIN 2022-375860 / [01] TOOL USED: TEMPERATURE CONTROLLER P/N 48VFL11 S/N AE-31448 DUE DATE 14 JUL 23.;[02] REPLACED FLOOR STRUCTURE ANGLE AND FASTENERS LOCATED LOCATED BS 692 AT BL 0 AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING 273A9110 SHEET 6 REV.A.;[03] CORRECTED STEP 2. REPLACED FLOOR STRUCTURE ANGLE AND FASTENERS LOCATED LOCATED BS 692 AT BL 0 AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING 273A9110 SHEET 6 REV.A. SEE INDIVIDUAL SIGNOFFS BELOW;[04] TASK COMPLETED; RII SEE INDIVIDUAL SIGN OFFS BELOW