What was found
CORROSION ON STRINGER CLIP AT AFT CARGO BAY BS767 S-26R. / [01] CORROSION ON CLIP AT AFT CARGO BAY BS767 S-26R FOUND TO BE OUT LIMITS DUE NO ALLOWABLE DAMAGE ON SRM PART WILL REPLACEMENT PER SRM 51-40-02-0G-0 PARA 9C;[02] REMOVED CLIP AT AFT CARGO BAY BS767 S-26R P/N 146A1010-90 I.A.W SRM 51-40-02-0G-0.;[03] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 1.;[04] FABRICATED ; DRILLED AND APPLIED CHEMICAL CONVERSION COATING ON NEW CLIP AT AFT CARGO BAY BS767 S-26R P/N 146A1010-90 WITH NEXT MATERIAL BAC1493-856#7075T62 LOT 5062963-1 I.A.W SRM 51-40-05-0G-0 ;SRM 51-20-01-0G-0 AND DWG 146A1010 AND OK TO PRIME.;[05] VERIFIED ACTION #4; OK TO PRIME GIVEN;[06] APPLIED OF BMS 10-11; TYPE I PRIMER TO THE SURFACE OF THE REWORKED AREA. REFER TO SOPM 20-41-02. AND OK TO INSTALL.;[07] VERIFIED ACTION #6; OK TO INSTALL GIVEN;[08] INSTALLED NEW CLIP AT AFT CARGO BAY BS767 S-26R I.A.W SRM 51-40-02-0G-0 AND DWG 146A1261.;[09] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 8.;[10] VERIFIED MEASUREMENT FIELDS ARE ACCURATE & COMPLETE.