What was found
MAIN CABIN FLOOR SUPPORT INTERCOSTAL CRACKED @ BL-0 BETWEEN. STA 380 AND STA 400 MKD DOT / [01] REMOVED MAIN CABIN FLOOR SUPPORT INTERCOSTAL CRACK @ BL-0 BETWEEN. STA 380 AND STA 400 IN REF SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED NEW MAIN CABIN FLOOR SUPPORT INTERCOSTAL @ BL-0 BETWEEN. STA 380 AND STA 400 IN REF SRM 51-40-05-0G-0;;[11] ENTER IN ERROR STEP # 10 INSTALLED EWIS PROTECTION AREA AT MAIN CABIN FLOOR SUPPORT INTERCOSTAL @ BL-0 BETWEEN. STA 380 AND STA 400;REMOVED MAIN CABIN FLOOR SUPPORT INTERCOSTAL CRACK @ BL-0 BETWEEN. STA 380 AND STA 400 IN REF SRM 51-40-02-0G-0;LOCATED AND DRILLED NEW MAIN CABIN FLOOR SUPPORT INTERCOSTAL @ BL-0 BETWEEN. STA 380 AND STA 400 IN REF SRM 51-40-05-0G-0;INSTALLED NEW MAIN CABIN FLOOR SUPPORT INTERCOSTAL CRACK @ BL-0 BETWEEN. STA 380 AND STA 400 IN REF SRM 51-40-02-0G-0 AND REMOVED EWIS PROTECTION AREA AT MAIN CABIN FLOOR SUPPORT INTERCOSTAL @ BL-0 BETWEEN. STA 380 AND STA 400;[12] VERIFIED STEPS 7; 8 AND 9;[13] VERIFIED STEP 11 AND 12