What was found
DOT A-24-01. MID CABIN FLOOR PANEL 231ZF HAS PULLED FIBERS ON TOP SIDE OF PANEL. / [01] EVALUATED DAMAGE; TOP SIDE OF PANEL IS REPAIRABLE IAW B737 SRM 53-00-50-2R-1 REPAIR 1.<BR><BR>CLEANED AND PREPPED REPAIR AREA IAW B737 SRM 53-00-50-2R-1 PAR 3 STEPS A;C;E; AND F. <BR><BR>VERIFIED REPAIR MATERIALS IAW B737 SRM 53-00-50-2R-1 TABLE 201; FIBERGLASS CLOTH BMS9-3 (A10269); RESIN EPOCAST 50A (A137335). REQUIRES OKAY TO BOND REPAIR PLIES.;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEPS 3K;L;M. TAP TEST GOOD. TOOLING-- AAR30347 DUE 4-30-23;[04] REPAIRED DAMAGE TO UPPER SURFACE OF FLOOR BOARD IAW SRM 53-00-50-2R-0 REPAIR GENERAL AND SRM 53-00-50-2R-1 REPAIR 1. TAP TEST GOOD;[05] VERIFIED STEPS COMPLETE; AUDIT COMPLIED WITH