What was found
CRACK ON FWD CARGO BAY STRINGER END AT BS 540 R/H STRINGER 25. / [01] SRM 53-00-03-1A-1 ALLOWABLE DAMAGE 1 AND SRM 53-00-03-2R-1 REPAIR 1 ARE APPLICABLE TO THIS A/C;[13] FABRICATED/LOCATED AND DRILLED -7 REPLACEMENT STRINGER SECTION. TREATED; IAW SRM 53-00-03-2R-1 REPAIR 1 AND IAW EA#22-153-02453-WIP1... OK TO PRIME;[14] VERIFIED CORRECTIVE ACTIONS 12 AND 13. OK TO PRIME;[15] PRIMED -7 REPLACEMENT STRINGER SECTIONT AND REWORKED AREA. <BR>IAW SRM 53-00-03-2R-1 REPAIR 1 AND IAW EA#22-153-02453-WIP1... OK TO INSTALL;[16] VERIFIED PRIMER APPLICATION TO REPLACEMENT STRINGER SECTION. OK TO INSTALL REPLACEMENT STRINGER SECTION ONLY.;[17] RECIEVED (3EA) -2 ANGLES AND (3EA) -3 CHANNELS FROM OSS TO HT T6 IAW SR 53-00-03-2R-1 REPAIR 1. CUSTOMER RO#878780-SWA/JOB# 552154 AND CUSTOMER RO#878781-SWA/JOB#552155;[18] FABRICATED/LOCATED AND DRILLED A -2 CHANNEL AND (2EA) -3 ANGLES AND EXTENDED THE -3 ANGLES MINIMUM 0.1 INCH PAST THE STRINGER FLANGE LIP. TREATED; IAW SRM 53-00-03-2R-1 REPAIR 1 AND IAW EA#22-153-02453-WIP1. OK TO PRIME[22] INSTALLED REPAIR PARTS -7 REPLACEMENT STRINGER SECTION; -2 CHANNEL AND -3 (2EA) ANGLES IAW SRM 53-00-03-2R-1 REPAIR 1 AND PER EA#22-153-02453-WIP1.<BR><BR>COMPLETED PARTIAL STEPS 1 AND 2;[23] VERIFIED CORRECTIVE ACTION 22.<BR>COMPLETED STEPS 1 AND 2;[24] CRACK ON FORWARD CARGO BAY STRINGER END AT BS 540 RH STRINGER 25 WAS REPAIRED IAW EA 22-153-02453;[25] VERIFIED ALL STEPS COMPLETE.<BR>VERIFIED MEASUREMENTS.