What was found
CRACK ANGLE FLOOR STRUCTURE BS 695 BL 0 CENTER SECTION 2022-418276 / [01] REPLACED ANGLE LOC. ON FLOOR STRUCTURE BS 695 BL 0 CENTER SECTION I.A.W. B737-700 SRM 51-40-02 AND SRM 51-10-02 ITEM 9 AND DWG 273A9110 REV. A SEE INDIVIDUAL SIGN-OFF BELOW;[02] REPLACED ANGLE LOC. ON FLOOR STRUCTURE BS 695 BL 0 CENTER SECTION I.A.W. B737-700 SRM 51-40-02 AND SRM 51-10-02 ITEM 9 AND DWG 273A9110 REV. A SEE INDIVIDUAL SIGN-OFF BELOW.. RII ITEM