What was found
FWD CABIN WET AREA FLOOR SUPPORT INTERCOSTAL CRACKED @ UPPER CAP LBL13 BETWEEN. STA 360 AND 400 MKD DOT / [01] REMOVED CRACKED INTERCOSTAL UPPER CHORD FROM FWD CABIN WET AREA FLOOR SUPPORT LBL 13 BETWEEN STA 380 AND STA 400 AS PER REFERENCE SRM 51-40-02-0G-0.;[02] VERIFIED STEP 1.;[03] LOCATED AND DRILLED HOLES ON NEW INTERCOSTAL UPPER CHORD AS PER REFERENCE SRM 51-40-05-0G-0.;[04] VERIFIED STEP 3. OK TO TREAT AND PRIMER.;[05] TREATED AND PRIMED NEW DRILLED HOLES AS PER REFERENCE AMM 51-21-41-370-803 AND AMM 51-21-72-370-804.;[06] VERIFIED STEP 5. OK TO INSTALL.;[07] INSTALLED NEW INTERCOSTAL CHORD AT FWD CABIN FLOOR SUPPORT LBL 13 BETWEEN STA 380 AND STA 400 AS PER REFERENCE SRM 51-40-02-0G-0 AND DWG# 143A5410.<BR><BR>JOB PERFORMED BY NOE ORTEGA 8426.;[08] VERIFIED STEP 7.;[09] C/W