What was found
L/H TRANSITION ANGLE STA 727E-817 HAS CORROSION / [01] REMOVED CORRODED LH TRANSITION ANGLE SECTION FROM STA 727D+9.5 TO 807+10.6 IAW SRM 53-00-53-2R-5.;[02] FABRICATED; LOCATED; DRILLED; ALODINED AND PRIMED ALL REPAIR PARTS IAW SRM 53-00-53-2R-5.;[03] LOCATED AND DRILLED FWD MOST SPLICE PLATE AT STA 727D+9.5 IAW SRM 53-00-53-2R-6.;[04] 1. JOSHUA PHIPPS (TECHNICIAN); 19-AUG-2022 05:33 UTC<BR>REMOVED CORRODED LH TRANSITION ANGLE SECTION FROM STA 727D+9.5 TO 807+10.6 IAW SRM 53-00-53-2R-5.<BR>2. JOSHUA PHIPPS (TECHNICIAN); 21-AUG-2022 09:11 UTC<BR>FABRICATED; LOCATED; DRILLED; ALODINED AND PRIMED ALL REPAIR PARTS IAW SRM 53-00-53-2R-5.<BR>3. JOSHUA PHIPPS (TECHNICIAN); 22-AUG-2022 03:28 UTC<BR>LOCATED AND DRILLED FWD MOST SPLICE PLATE AT STA 727D+9.5 IAW SRM 53-00-53-2R-6. VERIFIED.;[05] OK TO INSTALL THE L/H TRANSITION ANGLE.;[06] INSTALLED REPAIR PARTS AND TRANSITION ANGLE PER SRM 53-00-53-2R-5 AND 53-00-53-2R-6;[07] REQUIRES BONDED NUT PLATES TO BE INSTALLED FROM STA 727E -9 TO STA 807 +10 PER SRM 51-40-10.;[08] CORRECTED LINE #8;9 AND 22 IN MEASUREMENT FIELD.;[09] 6. JAMES RINCK (TECHNICIAN); 22-AUG-2022 06:20 UTC<BR>INSTALLED REPAIR PARTS AND TRANSITION ANGLE PER SRM 53-00-53-2R-5 AND 53-00-53-2R-6. INSPECTED.;[10] C/W STEP 1